Skip to content
Menu

Technology · Engines

Three readings of one crossing.
One value on the record.

Ship, shore and tank rarely agree. Published rules compare them, register one value inside the band and open a case for the rest.

Set the three readings

Band ±0.3% 0.3%Maximum permissible error of an accuracy class 0.3 dynamic liquid measuring system (custody transfer of crude oil and products).Source: OIML R 117-1:2019, Dynamic measuring systems for liquids other than water. Open the publication ↗ · readings illustrative

ContinueSchematic. Readings are illustrative; the band is the class 0.3 limit.

The finding

Three figures describe one cargo, and the gap between them is the work.

The ship counts what it loaded, the shore what it received, the tank what it holds. None is wrong; none is the record.

Each instrument measures the same crossing at a different hour, at a different temperature, to a different class. The engine does not average them and does not choose a favourite. It restates each reading to the same reference conditions, compares it with the value an independent flow computer recomputes at the crossing, and asks one question: does the difference sit inside the band the instrument can explain?

R1R2R3Ship figureCrossing, recomputedTank gaugewhat was loadedindependent valuewhat is held
SchematicWhere the three readings are taken. The crossing carries the two channels of the mark.
0.3%

Maximum permissible error of an accuracy class 0.3 dynamic liquid measuring system (custody transfer of crude oil and products)

OIML R 117-1:2019, Dynamic measuring systems for liquids other than water

0.3%Maximum permissible error of an accuracy class 0.3 dynamic liquid measuring system (custody transfer of crude oil and products).Source: OIML R 117-1:2019, Dynamic measuring systems for liquids other than water. Open the publication ↗
0.2%

Maximum permissible error of the meter alone in the same accuracy class

OIML R 117-1:2019, Dynamic measuring systems for liquids other than water

0.2%Maximum permissible error of the meter alone in the same accuracy class.Source: OIML R 117-1:2019, Dynamic measuring systems for liquids other than water. Open the publication ↗
15 °C and 101.325 kPa

Standard reference conditions for petroleum and liquid petroleum products

ISO 5024:1999, Petroleum liquids and liquefied petroleum gases, measurement, standard reference conditions

15 °C and 101.325 kPaStandard reference conditions for petroleum and liquid petroleum products.Source: ISO 5024:1999, Petroleum liquids and liquefied petroleum gases, measurement, standard reference conditions. Open the publication ↗

The reading

Raw readings become one registered value in four rules, none of them a judgement.

Deviation from the registered value, percent (illustrative)BandShip+0.62raw, outside+0.21restated+0.21inside the bandShore-0.41raw, outside-0.12restated-0.12inside the bandTank+0.18raw, inside+0.04restated+0.04inside the bandRegistered value
IllustrativeSchematic. Deviations are invented for illustration; the band is the class 0.3 limit.

01 · Received

Three readings arrive sealed.

Each reading reaches the ledger signed and time-stamped at creation. The engine holds it as received, with the instrument and the hour that produced it. Two of the three are outside the band.

02 · Restated

They are brought to one reference.

Quantities are restated at 15 °C and 101.325 kPa 15 °C and 101.325 kPaStandard reference conditions for petroleum and liquid petroleum products.Source: ISO 5024:1999, Petroleum liquids and liquefied petroleum gases, measurement, standard reference conditions. Open the publication ↗ with the meter factor and temperature correction shown. The correction is a versioned rule, not a decision.

03 · Compared

The band decides, not the analyst.

Inside the band is a difference the instrument class can explain. Outside it, something else is happening. The band is set once, dated and approved.

04 · Registered

One value goes on the record, or a case opens.

Inside: registered, with the rule version that produced it. Outside or incomplete: provisional, no fee earned, a case opened with a named public owner.

Instrument

Move the readings and watch the rule decide.

The defaults are illustrative. Take a reading away to see the engine call it unknown, never zero.

IllustrativeDeviations from the registered value, percent of volume at standard conditions.
Tolerance band

±0.2% is the meter alone 0.2%Maximum permissible error of the meter alone in the same accuracy class.Source: OIML R 117-1:2019, Dynamic measuring systems for liquids other than water. Open the publication ↗; ±0.3% the whole class 0.3 system 0.3%Maximum permissible error of an accuracy class 0.3 dynamic liquid measuring system (custody transfer of crude oil and products).Source: OIML R 117-1:2019, Dynamic measuring systems for liquids other than water. Open the publication ↗; ±0.5% is an illustrative looser band.

+0.21%
-0.12%
+0.04%
Ship+0.21%unknown, never zeroShore-0.12%unknown, never zeroTank+0.04%unknown, never zeroDeviation, percent (illustrative)
Decision
Registered
Spread
0.33 pointslargest minus smallest
Outside the band
None
Case and fee
No case; fee due on the registered unit

The metrology engine

A figure is registered only when its uncertainty budget closes inside the limit.

Seven sources of doubt are combined by root sum of squares. An over-limit or incomplete budget holds the registration.

IllustrativeStandard uncertainties in percent, each editable. Limit: ±0.3%, the class 0.3 system 0.3%Maximum permissible error of an accuracy class 0.3 dynamic liquid measuring system (custody transfer of crude oil and products).Source: OIML R 117-1:2019, Dynamic measuring systems for liquids other than water. Open the publication ↗.
0.10%
0.05%
0.02%
0.08%
0.06%
0.04%
0.01%
Meter factorunknownTemperatureunknownPressureunknownDensityunknownSamplingunknownProvingunknownTimingunknownCombinedLimitStandard uncertainty, percent (illustrative)
Combined
0.16%root sum of squares
Registration
Open
Reading
Every line is recorded and the combined figure sits inside the limit.

combined = √( meter factor² + temperature² + pressure² + … + timing² )

Exceptions

Every variance opens a case, and every case has a named public owner.

The engine proposes. It never closes a case, never merges a duplicate on its own and never assigns blame.

  1. Variance detected

    A reading falls outside its band, a record is missing or two records disagree.

  2. Case opened

    One case per variance, joined to every record involved by the event identifier.

  3. Routed to a named owner

    A public officer is named. The operator sees only its own cases, with a query clock.

  4. Evidence packet

    Readings, seals, rule version and uncertainty budget are assembled without a human edit.

  5. A public officer decides

    The system proposes. An algorithm never approves an adjustment.

  6. Closed by a new event

    The correction is a signed event with a reason, an author and a second approver from another team.

Record Asame event identifierreceived 09:14Record Bsame event identifierreceived 09:15Held for a person
SchematicSimulated records; times are invented.

One rulebook

Seven pairings share one rule engine, and each one can be read before it is run.

Record ACustody meter reading
Record BIndependent recomputation
Rule
An independent flow computer recomputes net standard volume from duplicated transmitter signals. The engine compares that value with the meter reading under the class band.
On variance
A case opens and is routed to a named public officer for metrology.
Record AOpening stock plus receipts less deliveries
Record BClosing stock and the declared return
Rule
Depot and tank balances roll forward from gauges and rack meters, then meet what the operator declares.
On variance
A case opens and is routed to a named public officer for the depot.
Record AQuantity measured at loading
Record BQuantity declared
Rule
The declared quantity is read against the measured one. The measured record is never edited to match.
On variance
A case opens and is routed to a named public officer for customs.
Record AQuantity on the bill of lading
Record BQuantity received at discharge
Rule
Loaded and discharged quantities are restated to the same reference conditions before they are compared.
On variance
A case opens and is routed to a named public officer for the cargo.
Record AVessel or vehicle track and seal events
Record BLoading and receipt records
Rule
A seal that opens, a stop that was not planned or a track that goes dark is placed beside the records that should explain it.
On variance
A case opens and is routed to a named public officer for movements.
Record AUsage records
Record BRated, billed and booked charges
Rule
Three comparisons in a row: usage to rating, rating to billing, billing to the finance ledger, each against versioned tariffs.
On variance
A case opens and is routed to a named public officer for revenue.
Record AInvoice
Record BPayment received
Rule
Each payment is matched to its invoice by the event identifier. A possible duplicate is held and shown, never merged automatically.
On variance
A case opens and is routed to a named public officer for treasury.

Replay

Rules are versioned, corrections are new events, and any month can be replayed.

A change to a rate, a threshold or a tariff creates a new dated version, approved once, with a reference-case test suite. Reprocessing creates a new revision and never an overwrite. An auditor can replay a month in isolation from its evidence manifest and reach the same statement.

Show the certificate as
Original eventvolume registeredrule version datedraw record digestCorrection eventreason and authorsecond approver,another teamCertificatesame numberrevision Arevision Bafter a correctionNothing is overwritten: each step is appended and chained to the one before.
SchematicChoose a revision to see which steps exist.

Search CFA Ventures