Designed against
A requirement in the design basis is drawn from a clause of the standard. The firm states the code and the edition it used.
Made by the firmThe firm · Standards we design to
Every requirement traces to a published code. Choose a domain and its tiles sort to the front.
Claims discipline
Each page says which claim it makes. The firm makes the first two, and only ever on a programme's own record.
A requirement in the design basis is drawn from a clause of the standard. The firm states the code and the edition it used.
Made by the firmA witnessed test shows the system meets the requirement, and the result is a signed record that an independent party can replay.
Made with the independent verifierAn accredited body issues a certificate for a stated scope and date. Only the certifier makes this claim. This site never makes it on a certifier's behalf.
Left to the certifierThe register
Filter by domain or by phase. Each code opens its source.
Information security management systems: requirements.
Frames the programme security case and the 24/7 security operations centre.
CFAPrivacy information management: extension to ISO/IEC 27001.
Shapes privacy by architecture: pseudonymisation at the edge, keys held by the regulator.
CFASecurity for industrial automation and control systems.
Sets the network zones and trust boundaries around meters, flow computers and collectors.
CFAWeb Authentication: phishing-resistant sign-in with public-key credentials.
Governs named accounts and dual control for any action with fiscal or evidential effect.
CFAWorld Customs Organization framework on supply chain security and trade facilitation.
Cited by the sector or technology page that relies on it, as a design reference.
CFASecure Hash Standard: specifies the SHA-256 algorithm used to compute the digest of each record.
Cited by the sector or technology page that relies on it, as a design reference.
CFADynamic measuring systems for liquids other than water.
Sets the permissible error that custody-transfer metering is designed and proved against.
CFAMeasurement of fluid flow in closed conduits: ultrasonic meters for gas.
Guides the gas verification meters used for energy at boundary crossings.
CFAAmerican Petroleum Institute Manual of Petroleum Measurement Standards.
Supplies the measurement practice behind proving, sampling and volume calculation.
CFAGeneral requirements for the competence of testing and calibration laboratories.
Frames the competence of the calibration and proving work the ledger records.
CFAPetroleum measurement: standard reference conditions.
Fixes the reference conditions in which every recorded volume is stated.
CFAElectricity metering data exchange: the DLMS/COSEM suite.
Cited by the sector or technology page that relies on it, as a design reference.
CFAElectricity metering equipment: general and particular requirements.
Cited by the sector or technology page that relies on it, as a design reference.
CFAWater meters for cold potable water and hot water.
Cited by the sector or technology page that relies on it, as a design reference.
CFAWater meters for cold potable water and hot water: metrological and technical requirements.
Cited by the sector or technology page that relies on it, as a design reference.
CFACharging management: charging data record (CDR) parameter description.
Defines the records read by copy-only collectors and by independent re-rating.
CFARoaming record exchange (transferred account procedure) and near real-time roaming data exchange.
Brings roaming records into the monthly verified revenue statement.
CFAEthernet service activation test methodology.
Guides the acceptance tests of backhaul links between sites and data centres.
CFAUniversal financial industry message scheme.
Shapes payment messages between government payment flows and the ledger.
CFAHarmonised interface specification for mobile money providers.
Shapes the wallet aggregates read for mobile-money reconciliation.
CFAOpenAPI Specification for describing HTTP interfaces.
Describes every published interface of the exchange gateway.
CFACommunication networks and systems for power utility automation.
Cited by the sector or technology page that relies on it, as a design reference.
CFAExtractive Industries Transparency Initiative global standard.
Frames royalty verification and the aggregates published to the public.
CFADue diligence for responsible supply chains of minerals from conflict-affected and high-risk areas.
Guides chain of custody from the licensed buying centre to export.
CFARecommendation and guidelines on establishing a single window.
Guides the design of single windows and port community systems.
CFAEU regulation on deforestation-free products: geolocation of production plots and due-diligence statements.
Shapes plot geolocation and due-diligence statements from plot to port.
CFAHarmonized Commodity Description and Coding System: the common goods nomenclature used in customs declarations.
Cited by the sector or technology page that relies on it, as a design reference.
CFAInternational convention on the simplification and harmonisation of customs procedures.
Cited by the sector or technology page that relies on it, as a design reference.
CFAWorld Trade Organization agreement on the implementation of Article VII of GATT 1994: the rules for the value of goods declared to customs.
Cited by the sector or technology page that relies on it, as a design reference.
CFAFreight containers: coding, identification and marking.
Cited by the sector or technology page that relies on it, as a design reference.
CFAFreight containers: electronic seals.
Cited by the sector or technology page that relies on it, as a design reference.
CFACarriage requirements for shipborne navigational systems, including AIS.
Underpins the vessel-tracking feeds that cargo and seal records rely on.
CFAInternational Water Association standard water balance and non-revenue water terminology.
Frames the water balance and the loss analytics of a district metered area.
CFATechnical characteristics of an automatic identification system using time-division multiple access in the VHF maritime mobile band.
Cited by the sector or technology page that relies on it, as a design reference.
CFAUnited Nations Convention on the Law of the Sea, Part V: the exclusive economic zone.
Cited by the sector or technology page that relies on it, as a design reference.
CFANo standard in this domain enters at this phase. Choose another phase.
From clause to test
One standard, followed through four steps until it is a test with a signed record.
OIML R 117-1:2019 states the maximum permissible error of a class 0.3 dynamic liquid measuring system as 0.3%, and of the meter alone as 0.2%.0.3%Maximum permissible error of an accuracy class 0.3 dynamic liquid measuring system (custody transfer of crude oil and products).Source: OIML R 117-1:2019, Dynamic measuring systems for liquids other than water. Open the publication ↗0.2%Maximum permissible error of the meter alone in the same accuracy class.Source: OIML R 117-1:2019, Dynamic measuring systems for liquids other than water. Open the publication ↗
In the design basis the limit is a requirement on an uncertainty budget. Each contribution is named: meter factor, temperature, pressure, density, sampling, proving and timing.
The metrology engine combines the contributions by root sum of squares and compares the result with the legal limit. A budget that is over the limit, or incomplete, holds the registration. No volume enters the ledger on a doubt.
At acceptance, witnessed proving records the system as found and as left. The record is signed and time-stamped at creation and kept in the evidence ledger, so an auditor can replay it.
Where standards bite
The three phases are the three slabs of the mark: Develop, Build and Operate.
Security and privacy standards frame the programme before any equipment exists. Measurement, interface and traceability standards bite while systems are built. A second group returns in operation, where calibration, sign-in and disclosure are repeated every day.
One dot is one standard of the register. Hover or focus a dot for its code.
Editions
Every requirement carries the edition it was drawn from. A new edition opens a review; it never changes a design silently.
Years are read from each code as published. Codes without an edition year are listed in the register without one: none is guessed.
Limits of the claim
Where a certificate exists, the certificate carries the claim, not this site.
A standard tells us what to build. A certificate tells others what was found.
Schematic. An empty frame: the lines are the certifier's to fill.
Where the standards become systems