A reading counts once sealed.
At the site, not later.

A meter reads, a prover and sampler check, a flow computer restates, a sealed box signs.

ContinueSchematic. Pulses travel the pipe and each reading is stamped into the sealed box.

Anatomy of a skid

Five instruments must agree before a quantity is registered.

A custody-transfer skid is a pipe run with an independent meter, a way to prove it, a sampler, a flow computer and a sealed box. Choose a part to see what it reads and when it holds a record.

flow computersealed edge boxmeterproversampler
Schematic. The meter, prover and sampler read the line; the flow computer and the sealed box turn those readings into one signed record.
Choose a part of the skid

Ultrasonic master meter

Sound timed along the flow gives a reference reading beside the operator's own meter.

Reads
Transit time of ultrasonic pulses along fixed chords, converted to volume at line conditions.
Checked by
The prover, and witnessed proving recorded as found and as left.
Held when
The meter factor drifts outside its limit, or proving is late.

Prover loop

A known volume is pushed through the meter and the difference is recorded.

Reads
A calibrated volume displaced between two detectors while the meter counts.
Checked by
A witness, so that as-found and as-left records are signed by someone other than the operator of the skid.
Held when
The run is incomplete or the two runs do not repeat.

Flow-proportional sampler

One sample for each increment of flow, so quality represents the whole parcel.

Reads
A small, proportional sample drawn from the line into a sealed pot.
Checked by
Laboratory analysis, under a competence standard for testing and calibration laboratories. ISO/IEC 17025:2017General requirements for the competence of testing and calibration laboratories.Source: Standard body publication: ISO/IEC 17025:2017. Open the publication ↗
Held when
The sample is not recorded: an incomplete budget holds the registration.

Independent flow computer

Duplicated signals are recomputed to net standard volume at reference conditions.

Reads
Two transmitter signals each for temperature and pressure, plus density and the meter pulses. Results are stated at 15 °C and 101.325 kPa.15 °C and 101.325 kPaStandard reference conditions for petroleum and liquid petroleum products.Source: ISO 5024:1999, Petroleum liquids and liquefied petroleum gases, measurement, standard reference conditions. Open the publication ↗
Checked by
The meter and the operator's own computer, which it never replaces.
Held when
The duplicated signals disagree beyond their tolerance.

Sealed edge box

Every reading is signed with a device-bound key at the moment it is created.

Reads
The flow computer's output, one way, with no path back into the skid.
Checked by
The centre, which rejects any record that fails its signature or its sequence.
Held when
The seal is broken or the sequence has a gap.

The uncertainty gate

An over-limit or incomplete uncertainty budget holds the registration.

Each source of error is combined by root sum of squares and set against the legal limit. Move an input and the registration follows the arithmetic.

Inputs, standard uncertainty in percent Illustrative

0.12%
0.05%
0.03%
0.08%
0.10%
0.06%
0.01%
legal limitthe bar and the limit line share one scalecombined by root sum of squares
Bar length is the combined uncertainty; each colour is that input's share of the combined variance. Inputs are illustrative.
Registered

Combined 0.19% against a limit of 0.3%.0.3%Maximum permissible error of an accuracy class 0.3 dynamic liquid measuring system (custody transfer of crude oil and products).Source: OIML R 117-1:2019, Dynamic measuring systems for liquids other than water. Open the publication ↗ The meter alone is held to 0.2%.0.2%Maximum permissible error of the meter alone in the same accuracy class.Source: OIML R 117-1:2019, Dynamic measuring systems for liquids other than water. Open the publication ↗

From reading to record

A reading is sealed at the moment it exists, not when it arrives.

Four things happen in the box, in this order, before a single byte leaves the site.

Edge recordsignal Asignal Bvolume at line conditionsnet standard volumesignaturetime stampsequencesequence track at the centregaprejected, replay requested

Duplicate

Two signals say the same thing, or the reading is held.

Temperature and pressure arrive twice, from two transmitters. The flow computer reads both, and a difference beyond tolerance stops the record.

Recompute

Volume is restated at reference conditions.

The independent computer recomputes net standard volume at 15 °C and 101.325 kPa.15 °C and 101.325 kPaStandard reference conditions for petroleum and liquid petroleum products.Source: ISO 5024:1999, Petroleum liquids and liquefied petroleum gases, measurement, standard reference conditions. Open the publication ↗ It does not copy the operator's figure; it derives its own.

Sign

The record is signed when it is created.

A device-bound key signs it, a time stamp and a sequence number are written into it, and it is encrypted before it leaves the box.

Check

The centre rejects what it cannot trust.

A bad signature or a break in the sequence is rejected, and the box replays from its local buffer. Nothing is repaired in transit.

Kinds of site

Every site starts by reading the instruments already there.

New hardware appears only where a witnessed test shows a gap. Choose a kind of site to see its kit.

Choose a kind of site
gatewaygauges read, not replacedportable kitweighbridgeseal reader, cameraAIS, GPSdual-energy X-ray, CThandheld XRFoperator sitecopy-only collectorsigned batches, one waysolar, batteryprobedrive and walk test points
Schematic. Each site reads existing instruments first and adds kit only where a witnessed test shows a gap.

Depot

Read the gauges and rack meters already there.

Reads
Gateways read existing automatic tank gauges and rack meters first.
Adds
Portable verification kits, brought to check what the gateway reads.
Rule
New hardware only where a witnessed test shows a gap.

Border

A movement is a weight, a density, a seal and a picture.

Reads
Weighbridge interfaces, density meters, electronic seal readers and cameras at the crossing.
Adds
Vessel tracking from terrestrial and satellite AIS; GPS where no incumbent feed exists.
Rule
Every item joins one record, so a seal read and a weight cannot be separated.

Exit point

Scan, then confirm purity in seconds.

Reads
Dual-energy X-ray, CT and cargo or vehicle scanners look for dense-metal concealment.
Adds
Handheld XRF analysers give purity in seconds, without damaging the item.
Rule
An unmatched item is referred to a public officer: the system never releases it.

Telecom site

A collector reads a copy and trusts no field it did not expect.

Reads
An out-of-band, copy-only collector at each operator site; fields are allow-listed, deny by default.
Adds
Unknown fields are quarantined, batches are signed, and identifiers are pseudonymised at the edge with keys the regulator holds.
Rule
Typically 2U to 4U of rack and under 1 kW per site (illustrative). Illustrative

Probe

Quality is measured from outside the network that sells it.

Reads
Fixed probes backed by solar panels and batteries, drive and walk tests, and generated test calls.
Adds
Test calls carry reserved identifiers, excluded from commercial totals.
Rule
A probe measures what a subscriber would experience, not what the operator reports.

Refusal

A record that fails its signature or its sequence is rejected, not repaired.

Rejecting is the safer fault. A fee is paid only on a registered, verified record, so a record that cannot be trusted earns nothing.

Choose what goes wrong
sequence at the centre, sample recordsgap: no recordnumber seen twicesignature failsREJECTED, NOT REPAIREDall eight accepted and written once
Schematic. Sample records are illustrative; the check is the same for every record that reaches the centre.

Every record carries a valid signature and the next number.

All eight arrive in order, each signed by the same device-bound key. The centre accepts them and writes them once.

A gap in the sequence is a rejection of the batch, not a guess.

The fifth number never arrives. The centre asks the box to replay from its local buffer rather than infer the missing record.

A number seen twice is refused the second time.

The fifth record arrives again. The sequence check refuses the repeat, so a replayed message cannot count twice towards a fee.

A changed record no longer matches its signature.

One value is changed in transit. The signature fails against the device-bound key and the record is rejected, with the failure itself kept as evidence.

Illustrative The point is the rule: a record is accepted whole or not at all, and the box keeps what it could not deliver until the centre can take it.

Limits

Two limits bound the measurement, and both are drawn to scale.

The whole measuring system is allowed a small error; the meter alone is allowed a smaller one. Both come from published standards.

Whole measuring system0.3%Meter alone0.2%
Both bars are maximum permissible errors in one accuracy class, drawn to one scale from the cited rows.0.3%Maximum permissible error of an accuracy class 0.3 dynamic liquid measuring system (custody transfer of crude oil and products).Source: OIML R 117-1:2019, Dynamic measuring systems for liquids other than water. Open the publication ↗0.2%Maximum permissible error of the meter alone in the same accuracy class.Source: OIML R 117-1:2019, Dynamic measuring systems for liquids other than water. Open the publication ↗
0.3%

Maximum permissible error of an accuracy class 0.3 dynamic liquid measuring system (custody transfer of crude oil and products)

OIML R 117-1:2019, Dynamic measuring systems for liquids other than water

0.3%Maximum permissible error of an accuracy class 0.3 dynamic liquid measuring system (custody transfer of crude oil and products).Source: OIML R 117-1:2019, Dynamic measuring systems for liquids other than water. Open the publication ↗
0.2%

Maximum permissible error of the meter alone in the same accuracy class

OIML R 117-1:2019, Dynamic measuring systems for liquids other than water

0.2%Maximum permissible error of the meter alone in the same accuracy class.Source: OIML R 117-1:2019, Dynamic measuring systems for liquids other than water. Open the publication ↗
15 °C and 101.325 kPa

Standard reference conditions for petroleum and liquid petroleum products

ISO 5024:1999, Petroleum liquids and liquefied petroleum gases, measurement, standard reference conditions

15 °C and 101.325 kPaStandard reference conditions for petroleum and liquid petroleum products.Source: ISO 5024:1999, Petroleum liquids and liquefied petroleum gases, measurement, standard reference conditions. Open the publication ↗
  • OIML R 117-1:2019Dynamic measuring systems for liquids other than water.OIML R 117-1:2019Dynamic measuring systems for liquids other than water.Source: Standard body publication: OIML R 117-1:2019. Open the publication ↗
  • API MPMSAmerican Petroleum Institute Manual of Petroleum Measurement Standards.API MPMSAmerican Petroleum Institute Manual of Petroleum Measurement Standards.Source: Standard body publication: API MPMS. Open the publication ↗
  • ISO 5024:1999Petroleum measurement: standard reference conditions.ISO 5024:1999Petroleum measurement: standard reference conditions.Source: Standard body publication: ISO 5024:1999. Open the publication ↗
  • ISO/IEC 17025:2017General requirements for the competence of testing and calibration laboratories.ISO/IEC 17025:2017General requirements for the competence of testing and calibration laboratories.Source: Standard body publication: ISO/IEC 17025:2017. Open the publication ↗
  • ISO 17089-1:2019Measurement of fluid flow in closed conduits: ultrasonic meters for gas.ISO 17089-1:2019Measurement of fluid flow in closed conduits: ultrasonic meters for gas.Source: Standard body publication: ISO 17089-1:2019. Open the publication ↗