Skip to content
Menu

Instrument 02 of 06

Seven errors add as areas.
One square meets the limit.

Each contribution to a measurement is a square. Their areas add into one combined square, and the combined side is compared with the legal limit.

Compare with the limit of
ContinueDefault illustrative values, areas drawn to scale.

Instrument 02

Seven small errors add as areas, so the largest square decides the result.

Set each contribution as a standard uncertainty in percent of reading, choose the limit and read the verdict. Defaults are illustrative; a contribution you cannot assess is unknown, never zero.

Contributions, percent of reading

Illustrative
1Residual error of the master meter after its factor is applied0.10
2Transmitter and sensor error converted to volume0.05
3Transmitter error converted to volume0.03
4Densitometer or laboratory error0.08
5Flow-proportional sampler representativeness0.06
6Repeatability of the witnessed proving run0.07
7Time-base error of the flow computer0.02
Legal limit 0.3%Maximum permissible error of an accuracy class 0.3 dynamic liquid measuring system (custody transfer of crude oil and products).Source: OIML R 117-1:2019, Dynamic measuring systems for liquids other than water. Open the publication ↗0.2%Maximum permissible error of the meter alone in the same accuracy class.Source: OIML R 117-1:2019, Dynamic measuring systems for liquids other than water. Open the publication ↗
Combined0.169%root sum of squares
Limit0.30%whole system (met-1)
Headroom0.131%56% of the limit used
Assessed7 of 7contributions

Squares 1 to 7, one per contribution; below, the combined square (solid) against the limit (dashed), on one scale so that areas compare. A dashed contribution is unknown and left out of the sum.

Within the limitThe budget is inside the limit: registration can proceed to the next check.

This is an illustration, not advice. It certifies no meter and no installation, it replaces no verification by the legal-metrology body, and every uncertainty is an input you set.

Why squares

Areas add and sides do not, so the small contributions barely move the result.

A fixed, illustrative drawing: the seven default contributions added one at a time, largest first.

14652370.1000.1280.1460.169limit 0.30side in percent of reading, illustrative
STEP 1 OF 5

The largest contribution is one square.

The meter factor stands at 0.10 percent of reading in the default budget. Alone, it is a combined uncertainty of 0.100 and nothing else.

STEP 2 OF 5

A second error adds its area, not its side.

Density at 0.08 does not lift the total to 0.18. Its area joins the first, and the combined side reads 0.128. Independent errors partly cancel.

STEP 3 OF 5

Three squares already carry 74% of the area.

Proving joins them. The combined side reads 0.146. Most of the budget now sits in three contributions, and the rest sit in the margins.

STEP 4 OF 5

The four small squares move the side by almost nothing.

Sampling, temperature, pressure and timing take it from 0.146 to 0.169. Perfecting them would be effort spent where the area is not.

STEP 5 OF 5

The limit is a square too, and the budget sits inside it.

The whole-system limit is 0.3%0.3%Maximum permissible error of an accuracy class 0.3 dynamic liquid measuring system (custody transfer of crude oil and products).Source: OIML R 117-1:2019, Dynamic measuring systems for liquids other than water. Open the publication ↗. The headroom is the distance between the two sides, and an over-limit square holds the registration.

What to improve

Improve the largest square first: it buys more headroom than the three smallest together.

Reduce one contribution at a time and see how much of the combined uncertainty it removes. Gains are in points of reading, on your own inputs.

Reduce a contribution by
Headroom gained, percent of reading (50% reduction)
ContributionGainPoints
1. Meter factor0.024
2. Temperature0.006
3. Pressure0.002
4. Density0.015
5. Sampling0.008
6. Proving0.011
7. Timing0.001

Illustrative Bar length: gain against a full scale of 0.12 points.

Headroom is the gap between the combined uncertainty and the limit. Reducing a contribution helps in proportion to its area, so the squares that look small in the drawing return little for the work they cost.

The ranking depends on your inputs. Raise the density contribution and it takes the lead; mark one unassessed and its gain reads n/a, because an unknown cannot be improved.

Spend the first unit of effort on the biggest square.

The registration gate

An over-limit budget and an incomplete budget both hold the registration.

No record, no fee: until the budget is complete and inside the limit, an event stays provisional and earns nothing. Try the three outcomes.

BudgetWithin the limitRegistered: the event can earn its feeOver the limitHeld: reduce a contribution, run againA contribution not assessedHeld: assess it first, then run again
Within the limitCombined 0.169% against a limit of 0.30%

Three outcomes

Illustrative

The three buttons set the same inputs as the instrument above, so the squares there move too. A partial sum can look comfortable while a contribution is still missing, which is why an incomplete budget holds the registration whatever the number reads.

Holding is not a penalty. It keeps an unproven reading out of the public record until someone has proved it.

The working

Every step of the sum is shown, so an auditor can replay it.

The ledger recomputes with your inputs. The standards beside it are the ones the model is read against.

Budget ledger, percent of reading (illustrative)
Contributionuu squaredShare of area
1. Meter factor0.100.010035%
2. Temperature0.050.00259%
3. Pressure0.030.00093%
4. Density0.080.006422%
5. Sampling0.060.003613%
6. Proving0.070.004917%
7. Timing0.020.00041%
Sum of squares0.0287
Square root: combined0.169
OIML R 117-1:2019OIML R 117-1:2019Dynamic measuring systems for liquids other than water.Source: Standard body publication: OIML R 117-1:2019. Open the publication ↗

Dynamic measuring systems for liquids other than water.

ISO 5024:1999ISO 5024:1999Petroleum measurement: standard reference conditions.Source: Standard body publication: ISO 5024:1999. Open the publication ↗

Petroleum measurement: standard reference conditions.

ISO/IEC 17025:2017ISO/IEC 17025:2017General requirements for the competence of testing and calibration laboratories.Source: Standard body publication: ISO/IEC 17025:2017. Open the publication ↗

General requirements for the competence of testing and calibration laboratories.

API MPMSAPI MPMSAmerican Petroleum Institute Manual of Petroleum Measurement Standards.Source: Standard body publication: API MPMS. Open the publication ↗

American Petroleum Institute Manual of Petroleum Measurement Standards.

The reference conditions of a petroleum measurement are explicit: 15 °C and 101.325 kPa15 °C and 101.325 kPaStandard reference conditions for petroleum and liquid petroleum products.Source: ISO 5024:1999, Petroleum liquids and liquefied petroleum gases, measurement, standard reference conditions. Open the publication ↗. A volume without them is not a record.

Method and limits

Four rules fix the arithmetic, and four limits say what it cannot do.

Standard uncertainty

Each contribution is entered as a standard uncertainty in percent of reading: meter factor, temperature, pressure, density, sampling, proving and timing.

Square

Each is squared. The square is its area, in the same units as every other.

Add

The areas are summed. Independent contributions add this way, which is why they partly cancel.

Root and compare

The square root of the sum is the combined uncertainty, compared with the limit. Over the limit, or any contribution unknown, and the registration is held.

0.3%

Maximum permissible error of an accuracy class 0.3 dynamic liquid measuring system (custody transfer of crude oil and products)

OIML R 117-1:2019

0.3%Maximum permissible error of an accuracy class 0.3 dynamic liquid measuring system (custody transfer of crude oil and products).Source: OIML R 117-1:2019, Dynamic measuring systems for liquids other than water. Open the publication ↗
0.2%

Maximum permissible error of the meter alone in the same accuracy class

OIML R 117-1:2019

0.2%Maximum permissible error of the meter alone in the same accuracy class.Source: OIML R 117-1:2019, Dynamic measuring systems for liquids other than water. Open the publication ↗
15 °C and 101.325 kPa

Standard reference conditions for petroleum and liquid petroleum products

ISO 5024:1999

15 °C and 101.325 kPaStandard reference conditions for petroleum and liquid petroleum products.Source: ISO 5024:1999, Petroleum liquids and liquefied petroleum gases, measurement, standard reference conditions. Open the publication ↗

Independence is assumed

Root sum of squares is exact only for independent contributions. Correlated errors need a covariance term that this model does not carry.

No coverage factor

The combined standard uncertainty is compared with the limit as it stands. Where the rules call for an expanded uncertainty, that is a further step.

A class limit, not a certificate

The two limits are maximum permissible errors of a class of system. Meeting them in a model certifies no installation.

Tested arithmetic

The model has automated tests: a 3 and 4 pair combine to 5, areas add, an unassessed contribution makes the budget incomplete, and an exact tie with the limit is within it.

Search CFA Ventures