Potential case 05 of 08
Non-revenue water,
in a coastal city.
Metered districts show, hour by hour, where a coastal city’s water is lost before it is billed.
The situation, from public evidence
Non-revenue water is a loss twice over: the water, and the revenue it would have earned.
Non-revenue water is the part of what a utility puts into its network that earns nothing: leakage, consumption that is never metered or paid, and water authorised free of charge. The standard water balance of the International Water Association names each part so that each can be measured on its own.IWA water balanceInternational Water Association standard water balance and non-revenue water terminology.Source: Standard body publication: IWA water balance. Open the publication ↗
The design
District meters turn one network into twelve questions a crew can answer.
Divide the network into district metered areas.
Boundary valves and one meter at each inlet turn a single network into districts whose inflow can be read on its own, each small enough for one crew to work through.
Read every inlet through the night.
In the small hours legitimate use is at its lowest, so the minimum that still flows is mostly leakage. A copy of each meter’s signal is read; nothing is written into the utility’s control system.
Rank districts by night-flow excess.
Subtract the night use expected from demand and what remains orders the districts. The ranking proposes where to look first. It decides nothing.
Send crews where the ranking points, then measure again.
Every repair is verified at the same meter and the district is re-ranked. A repair that does not lower the night minimum is not counted as recovered.
Instrument
The night minimum falls where leaks are fixed, and the ranking moves with it.
Choose a district and set how much of its leakage has been found and fixed. All values are illustrative units per hour.
Low town
Illustrative input. The share of this district's leakage located, repaired and verified at its meter.
Illustrative Districts, demands and leakage are invented units per hour, generated for this page.
- Night minimum
- 54.0units per hour
- Excess over expected use
- 46.0calculated
- Rank of twelve
- 1by excess
- 1B346.0
- 2A238.0
- 3C230.0
- 4B127.0
- 5C424.0
- 6A421.0
- 7B418.0
- 8C315.0
- 9B214.0
- 10A112.0
- 11A39.0
- 12C17.0
Illustrative deployment plan
Metering comes before repair, and the first ranking arrives in the last third of 90 days.
Illustrative financing
A performance contract pays for recovered water, measured at the district meter.
Payment follows the verified fall in losses. The baseline is fixed by an independent water balance before any work starts.
The utility’s baseline revenue
Kept whole. The baseline comes from an independent audit of the water balance.
The public owner’s share of recovered revenue
Paid first, from an escrowed collection account in which the operator is not a signatory.
The fee on verified recovery
Paid only where a repair lowers the night minimum at its meter. No record, no fee.
Debt service and reserve accounts
Senior and local-currency lenders, with reserves topped up before any distribution.
Investor return
Equity with standby commitments, and local investor tranches.
Upside above the reference trajectory
Shared with the public owner when recovery runs ahead of the agreed path.
Governance
The ranking proposes; a named utility engineer decides where a crew goes.
- 01
District meters
Their signals are read as copies; the utility’s control system is never written to.
- 02
The night-flow ranking
Orders districts by excess. No algorithm may approve an adjustment.
- 03
A named utility engineer
Decides which district to enter and which crew to send.
- 04
An independent auditor
Verifies the water balance and each claimed recovery from its evidence manifest.
- 05
The record
A recovery enters the record only when the district meter shows it. Anything incomplete stays provisional and earns no fee.
What would be measured
Each indicator states how it was obtained, and a gap stays a gap.
- Measured
System input per district
Inlet meter readings, with an uncertainty budget per meter.
- Measured
Night-flow minimum
The lowest inflow of each district in the night window, read continuously.
- Calculated
Excess over expected night use
Night minimum less the legitimate use expected from demand; the rule is versioned and dated.
- Estimated
Customer meter accuracy
As-found and as-left tests on a stratified sample, with a published confidence interval.
- Calculated
Recovered volume verified
Share of claimed recoveries confirmed at the district meter and by audit sampling.
Risks
The largest risks sit in the records and the meters before they sit in the pipes.
Network records do not match the ground
Surveys come before design, and district boundaries are proven by closing tests.
Customer meters under-register
Apparent losses hide in meter error, so meters are tested before they are replaced.
A boundary valve leaks
A district with a leaking boundary is flagged and its ranking labelled provisional.
Leaks return after repair
Maintenance and renewal waves are part of the term, and the night minimum is watched continuously.
The baseline is disputed
The baseline is audited and published before the first payment.
Where this leads