Skip to content
Menu

Sector 01 of 12

Every barrel crosses a line.
Measure it there.

Oil and gas change hands at boundaries. We build the independent metering that writes one signed record at each crossing, beside the operator's own meters.

ContinueSchematic. Quantities are illustrative; the limits are published.

What is at stake

A barrel is paid for where it crosses a boundary, so that is where it must be measured

Crude, products, bunkers and pipeline gas change hands at a handful of physical points. Measure those points independently and the rest of the system has something firm to reconcile against.

FieldWellsGatheringCustodyTerminalCustodyShipCustodyRefineryBalanceDepotBalanceRackCustodyFieldWellsGatheringCustodyTerminalCustodyShipCustodyRefineryBalanceDepotBalanceRackCustody
Schematic. A channel marks each point where title or responsibility changes.
USD 40bnUSD 40bnEstimated export under-invoicing of extractive commodities from Africa in 2015.Source: UNCTAD, Economic Development in Africa Report 2020. Open the publication ↗

Estimated export under-invoicing of extractive commodities from Africa in 2015.

UNCTAD, Economic Development in Africa Report 2020

USD 88.6bnUSD 88.6bnEstimated illicit capital flight from Africa per year, about 3.7 percent of the continent's GDP.Source: UNCTAD, Economic Development in Africa Report 2020. Open the publication ↗

Estimated illicit capital flight from Africa per year, about 3.7 percent of the continent's GDP.

UNCTAD, Economic Development in Africa Report 2020

0.3%0.3%Maximum permissible error of an accuracy class 0.3 dynamic liquid measuring system (custody transfer of crude oil and products).Source: OIML R 117-1:2019, Dynamic measuring systems for liquids other than water. Open the publication ↗

Maximum permissible error of an accuracy class 0.3 dynamic liquid measuring system (custody transfer of crude oil and products).

OIML R 117-1:2019, Dynamic measuring systems for liquids other than water

The first figure is for all extractive commodities, not oil alone. The third is the permitted error of the measurement system itself.

Where value escapes

Value escapes in three places, and each has a physical cause

Choose one. The mechanism is the same in every producing or transit system: a quantity, a set of conditions, a record.

Cause

An unproved meter reads wrong by an amount nobody has measured

A custody meter drifts between provings. Without a witnessed proving, the as-found error is unknown and the quantity is only declared.

The architecture adds proving with as-found and as-left records, so a drift is seen as a step, not a surprise.

PERMITTED BANDERRORTIMEprovingprovingprovingUNPROVEDProved on schedule
Schematic. No values are implied.

Volume depends on temperature, pressure and density

A cargo is priced at standard reference conditions, 15 °C and 101.325 kPa15 °C and 101.325 kPaStandard reference conditions for petroleum and liquid petroleum products.Source: ISO 5024:1999, Petroleum liquids and liquefied petroleum gases, measurement, standard reference conditions. Open the publication ↗. The correction needs three signals from the same crossing.

If one transmitter supplies them, one error corrects every barrel the same wrong way. Duplicated transmitters and an independent flow computer remove that single point.

OBSERVED VOLUMETemperature correctionPressure correctionNET STANDARD VOLUMEat the referenceconditions
Schematic. Lengths are not to scale.

Three readings of one crossing disagree and nobody owns the gap

Ship, shore and tank figures differ at every crossing. A system that averages them hides the gap.

The reconciliation engine treats them as three readings, compares the spread with the uncertainty budget and routes every variance to a named public owner.

SHIPSHORETANKSpread, compared with the budget
Schematic.

What we build

We add a second evidence chain beside the operator's meters and read copies only

The operator keeps its meters, flow computers and ledgers. Our chain reads copies of the same signals through taps that cannot write back.

OPERATOR'S SYSTEM, UNCHANGEDMeter runOperatorflow computerOperatorcontrol systemcopy-only tapsSECOND EVIDENCE CHAINDuplicatedtransmittersIndependentflow computerEdgesealingOne-waydata diodeEvidenceledgerENGINES AND AUTHORITY VIEWMetrologyengineReconcil-iationCommandcentre
Schematic. Dots mark where a link is one-way.

Beside, never inside. The chain never writes into an operator's control system. One-way data diodes and read-only interfaces carry copies to the ledger.

  • Ultrasonic master meters with prover interfaces, and witnessed proving with as-found and as-left records.
  • Independent flow computers that recompute net standard volume from duplicated transmitter signals.
  • Flow-proportional samplers, and for gas, verification meters with gas chromatographs for energy.
  • Depots and racks: gateways read existing tank gauges and rack meters first. New hardware goes in only where a witnessed test shows a gap.
  • A national hydrocarbon ledger, with a fee fixed per registered unit.

One barrel

A barrel leaves a tank as a reading and arrives in the ledger as a record

Four steps from the tank to the sealed event. Scroll to move the barrel.

TANKBOUNDARYMASTER METERSHIPTHREE READINGSEVIDENCE LEDGER
Schematic. One unit, five records.
Step 1 of 4

It leaves a tank as a signed reading

Existing automatic tank gauges are read first. A portable verification kit is used only where a witnessed test shows a gap. The reading is signed and time-stamped at the gauge, with a device-bound key, before it travels.

Step 2 of 4

It crosses the boundary through a proved meter

Duplicated transmitters feed an independent flow computer, which recomputes net standard volume at 15 °C and 101.325 kPa15 °C and 101.325 kPaStandard reference conditions for petroleum and liquid petroleum products.Source: ISO 5024:1999, Petroleum liquids and liquefied petroleum gases, measurement, standard reference conditions. Open the publication ↗. The meter was proved by a witnessed prover run, and its as-found and as-left records are kept.

Step 3 of 4

Ship, shore and tank give three readings of it

None is averaged away. The reconciliation engine compares their spread with the uncertainty budget. A variance beyond tolerance opens an exception, routed to a named public owner.

Step 4 of 4

The event is sealed, and only then earns a fee

An event registers only if it is complete and inside tolerance. The state's share is paid first from an escrowed account. An incomplete or out-of-tolerance event stays provisional and earns nothing.

Instruments

A crossing registers only when its uncertainty budget closes inside the legal limit

Both instruments start from illustrative inputs. Change them and watch the record register or stay provisional.

Uncertainty budget Illustrative inputs
0.10%
0.05%
0.04%
0.02%
0.06%
0.08%
0.01%

Terms in percent of volume, combined by root sum of squares. The meter term is also checked alone against the meter limit 0.2%0.2%Maximum permissible error of the meter alone in the same accuracy class.Source: OIML R 117-1:2019, Dynamic measuring systems for liquids other than water. Open the publication ↗.

Combined
0.157%
Legal limit0.3%Maximum permissible error of an accuracy class 0.3 dynamic liquid measuring system (custody transfer of crude oil and products).Source: OIML R 117-1:2019, Dynamic measuring systems for liquids other than water. Open the publication ↗
0.3%
Headroom
0.143%
Largest term
Meter
LIMIT 0.3%OVER LIMITSHARE OF EACH TERMMeterProvingTemperaturePressureDensitySamplingTiming
RegistersThe combined uncertainty is inside the legal limit and the meter term is inside the meter limit: the event can be registered.
Three readings of one crossing Illustrative inputs
1000.0
1000.6
999.8
0.30%

Figures in thousand barrels, illustrative. The default tolerance echoes the system limit 0.3%0.3%Maximum permissible error of an accuracy class 0.3 dynamic liquid measuring system (custody transfer of crude oil and products).Source: OIML R 117-1:2019, Dynamic measuring systems for liquids other than water. Open the publication ↗ but is an input, not a rule.

Mean
1 000.1
Spread
0.08%
Tolerance
0.30%
SHIPSHORETANK9951 0001 005SPREAD
ReconciledThe three readings sit inside the tolerance: the crossing closes and the record can be sealed.

How it is financed and delivered

A service that pays for itself needs no state guarantee, and the order of payment is the contract

The generic concession model: the developer finances, builds and operates, is paid from the service, and hands everything back.

Escrowed collection accountThe operator is not a signatory1State's share, paid first2Fee, on registered units only3Debt service and reserves4Upside above trajectory, shared
Schematic. Order of payment, not amounts.

The developer prepares before the contract takes effect, at its own cost and risk, then finances the build with private equity under standby commitments and senior and local-currency debt, with development-finance and export-credit routes where they fit.

The fee is fixed per registered unit and is at risk against published KPIs. Termination and buy-out formulas are written in advance. Concession terms are commonly 15 to 20 years Illustrative, and assets, code and skills return free of charge.

Track
  1. ProposedA node is listed against the inventory.
  2. SurveyedSite and signals checked on foot.
  3. DesignedInterface schedule agreed.
  4. InstalledFactory-tested skid placed.
  5. VerifiedBy the legal-metrology body.
  6. CommissionedThe node starts to register.
  1. A1 InterfaceEach interface passes its contract tests.
  2. A2 ComponentEach component meets its specification.
  3. A3 IntegrationComponents work together.
  4. A4 OperationalProcedures run end to end.
  5. A5 ServiceService levels read from telemetry.
  6. A6 TransferThe owner can run it alone.

Standards

Every measurement claim is anchored in a published standard, designed against and never claimed as certified

The codes below are the ones the oil and gas architecture is designed against.

  • OIML R 117-1:2019OIML R 117-1:2019Dynamic measuring systems for liquids other than water.Source: Standard body publication: OIML R 117-1:2019. Open the publication ↗

    Custody transfer of liquidsDynamic measuring systems for liquids other than water. Sets the accuracy classes the system and the meter are judged against.

  • API MPMSAPI MPMSAmerican Petroleum Institute Manual of Petroleum Measurement Standards.Source: Standard body publication: API MPMS. Open the publication ↗

    Petroleum measurementAmerican Petroleum Institute Manual of Petroleum Measurement Standards. The reference manual for proving, sampling, density and volume correction.

  • ISO 5024:1999ISO 5024:1999Petroleum measurement: standard reference conditions.Source: Standard body publication: ISO 5024:1999. Open the publication ↗

    Reference conditionsPetroleum measurement: standard reference conditions. Fixes the conditions to which every volume is restated.

  • ISO 17089-1:2019ISO 17089-1:2019Measurement of fluid flow in closed conduits: ultrasonic meters for gas.Source: Standard body publication: ISO 17089-1:2019. Open the publication ↗

    Gas measurementMeasurement of fluid flow in closed conduits: ultrasonic meters for gas. Governs ultrasonic meters for pipeline gas.

  • ISO/IEC 17025:2017ISO/IEC 17025:2017General requirements for the competence of testing and calibration laboratories.Source: Standard body publication: ISO/IEC 17025:2017. Open the publication ↗

    LaboratoriesGeneral requirements for the competence of testing and calibration laboratories. Competence of the laboratories that test samples and calibrate instruments.

  • ISO/IEC 27001:2022ISO/IEC 27001:2022Information security management systems: requirements.Source: Standard body publication: ISO/IEC 27001:2022. Open the publication ↗

    Information securityInformation security management systems: requirements. The management system around the evidence chain.

  • IEC 62443IEC 62443Security for industrial automation and control systems.Source: Standard body publication: IEC 62443. Open the publication ↗

    Control systemsSecurity for industrial automation and control systems. Zones and conduits between the evidence chain and operational technology.

Search CFA Ventures

Type to search.